The fourth mode

Geatron OGF Series It doesn’t follow the grid: it forms it, from within it too

Storage made in Europe that makes the most of your PV, lowers your energy costs and protects your production without disconnecting from the grid.

No commitment · Engineering reply within 24 working hours

Una unidad Geatron OGF al aire libre, al anochecer

The switchboard, at 13:00

Covering 100 % of the active power does not empty the board

Large electric motors in an industrial plant room

The active meter looks like a Sunday. The reactive one, like a Monday.

When the roof matches consumption, the active power crossing the transformer falls to almost zero. The motors’ reactive power still comes in from the street.

The five symptoms on the board
  • The power factor at the boundary collapses. The plant did not get worse: we removed the numerator and left the denominator.
  • The busbars are still loaded. Current circulates between the PV and the loads even while the meter sleeps.
  • The capacitors are still in, with the motors down. With the transformer reactance they form a resonant circuit, and the fifth harmonic is amplified.
  • The anti-islanding relay runs out of signals. If P and Q cross zero at the same time, it cannot tell a grid that is present from one that is gone.
  • Nobody on the busbars sets the frequency. With no local inertia, how fast it falls is decided by the street.

A unit that forms the waveform changes what the board does for a living. And all of this is measured with an analyser in your own switchboard.

The switchboard at midday, in full Power factor 0.98 without a capacitor bank

Switchboard · 13:00 · the PV covers the active powerIllustrative recreation
The streetGeatron OGFPhotovoltaicsMotors and loadsBusbarsP · activeQ · reactiveQ · reactive
Active power at the boundary
≈ 0 · the meter looks like a Sunday
Reactive power at the boundary
The motors’ · like a Monday
Boundary power factor
Collapses
Voltage and frequency
Set by the street

The solution

Geatron OGF Series

The fourth mode, because there are four. Grid-following, switched hybrid and islanded forming already existed. The fourth, On-Grid Grid-Forming, forms the grid without disconnecting from it. The four modes, side by side

What your plant gains

Savings

  • Pay less for the energy you use.
  • Every renewable kWh, put to use.
  • Stable machines, processes without stoppages.
Illustrative

Supply quality

  • The line without micro-outages.
  • It doesn’t switch over: it is already forming the grid.
Illustrative
Geatron OGF Series unit

01 Geatron Control Core

It sets the reference in the plant.

Illustrative

It imposes voltage and frequency with VSM control, like a synchronous machine. If the grid drops, there is nothing to switch over.

02 AC/DC modules

More power, without upgrading the grid connection.

Illustrative

The bidirectional modules add their power to the grid’s when the process asks for it. And it can be expanded.

03 DC/DC converters

No excess-power charges on the bill.

Illustrative

They discharge the battery at the peak so the meter stays within the contracted power.

04 Geatron View

The plant, live. The data, yours.

Illustrative

Live

P
412 kW
Q
38 kvar
cos φ
0.99
SOC
78 %

On the unit’s screen and remotely. The history stays in the unit, not in someone else’s cloud.

It doesn’t switch over. It was already forming the grid.

Listen to Geatron OGF

Proof, not promise

  • Measured

    0.89 → 0.98

    Power factor with no capacitor bank, on the customer’s own analyser

    See the test
  • Measured

    50 → 200 kVA

    A building on a temporary supply, six months on its own grid

    See the case
  • Measured

    −120 kVA

    Contracted power that same building no longer needs

  • In service

    250 → 700 kVA

    It started at 250 kVA and now runs 700: power is expandable. At a food industry plant

    See the case

Try it

Cut the grid. The plant keeps running.

Press “Simulate a grid failure” and watch the oscilloscope. At the top, in grey, the grid voltage. In the middle, in amber, what your machines receive with Geatron OGF. At the bottom, in red, a system that has to switch over to battery.

  1. 1The grid fails: the grey line goes flat.
  2. 2A switching system cuts out while it changes mode: a gap in the red line.
  3. 3With Geatron OGF the amber line carries on unchanged: it was already forming the grid, there is nothing to switch.
Grid present · Geatron OGF in parallel --:--:--.---

Single-line diagram

GRID 400 V · 50 Hz Q1 · closed BUSBAR GEATRON OGF forms the grid CRITICAL LOADS

Oscilloscope · phase voltage

  • Grid (connection)
  • Your loads, with Geatron OGF
  • A switching system
Voltage at connection
400 V
Voltage at loads
400 V
Frequency at loads
50.00 Hz
Energy source
Grid + Geatron OGF
Switchovers
0
  1. System in parallel with the grid. No events.

Illustrative recreation · not to time scale

Geatron View

The control room of your plant.

Power, status and alarms by the second, on the unit’s screen and remotely. The data come from the Geatron Control Core, the brain of the unit, and the history is stored in the unit, not in someone else’s cloud.

LiveGrid-forming · in parallel with the gridIllustrative recreation
Active power412kW
Reactive38kvar
cos φ0.99
State of charge78%
Frequency50.00Hz
Contracted · 250 kW

Plant consumption—

Drawn from the grid—

Covered by the battery—

Plant consumptionDrawn from the gridOn site · in the office · on your phone

Who is behind it

Manufacturer, not integrator.

  1. 01

    In-house power electronics

    AC/DC modules and DC/DC converters designed in-house.

  2. 02

    In-house control

    VSM control runs on the Geatron Control Core, inside the unit. Not on a PC or in a cloud.

  3. 03

    Made in Europe

    Six product generations since 2000.

  4. 04

    In-house maintenance

    Operation and maintenance by Kuantica, with an extendable 10-year warranty.

ISO 9001 · Quality management system · OCA Global ISO 9001Quality management system
ISO 14001 · Environmental management system · Iscertia ISO 14001Environmental management system

EU declaration of conformity (ISO/IEC 17050-1) against grid-connection, electrical safety, electromagnetic compatibility and lithium battery standards: see the standards.

Backing

What you buy is continuity

The unit is half the commitment. The other half is who answers when something fails.

Assembly room at the Kuantica centre in Rivas-Vaciamadrid, with the unit disconnected
Assembly roomUnit disconnected
Unidad Geatron OGF en un campo de cereal al anochecer
A Kuantica technician next to the Geatron OGF unit and its battery cabinets in a plant room
100%

Operation and maintenance

O&M entirely on us. You do not manage suppliers.

10years

Unit warranty

Extendable, with no time limit.

6th gen.

No obsolescence

Continuously updated.

QHP

Verified quality

Continuous verification protocol.

Projects

Engineering in operation

In service, from 120 kW to 1.9 MW. View all projects.

+5

Contact

The grid gives no warning. It just sends the bill.

Let us talk about your plant

Tell us your consumption, your contracted power and where your critical points are. Our engineering team answers within one working day.

Installer or engineering firm? We work through one concessionaire per province: one province, one point of contact. See the territorial concession

    Contact our engineers